Product Details
1.Product Description
CoEpower APF series Dynamic harmonic compensation filter AHF(APF for short is a new type power electronic product with functions of dynamic harmonic compensation (varying amplitude and frequency) 、reactive power compensation (leading or lagging and three phase unbalance correction.Dynamic harmonic compensation filter AHF is a controllable current device preventing resonance on mechanism, not generating nor amplifying harmonics.
Dynamic harmonic compensation filter AHF can be used to filter out harmonics in the power system which are significantly below the switching frequency of the filter.The main difference between Dynamic harmonic compensation filter AHF and passive power filters is that AHF mitigates harmonics by injecting active power with the same frequency but with reverse phase to cancel that harmonic, where passive power filters use combinations of resistors (R), inductors (L) and capacitors (C) and does not require an external power source or active components such as transistors. This difference, make it possible for AHF to mitigate a wide range of harmonics.
2,Product parameters
Rated Compensation
Current
|
25-150A in wall mounted
200-750A cabinet parallel configuration
|
Altitude Operating
Limit
|
1% up 2000m(2000-4000m)
The power decrease by 1% for every additional 100m
|
Rated Voltage(V)
|
220V/400V/480V/690V |
Operating
temperature
|
-10℃ ~ +45℃/ |
Rated Frequency (Hz)
|
50HZ/60HZ |
Relative
Humidity
|
≤95%,Non-condensing |
Functions |
1.Harmonic Compensation
2.Unbalance Correction
3.Power Factor Correction
|
Neutral Filtering
Capability
|
Yes |
Network Configuration
|
3P4W |
Noise Level |
<60db |
Parallel Operation |
750A Per Cabinet
Or
Customized
|
CT Ratio |
100;5~6000:5 |
Harmonic Compensation
Efficiency
|
>97% |
Topology Design |
3 Level |
Harmonic Compensation
Capability
|
THDi<5% |
Neutral Compensation
Capacity
|
3 times Rating |
Harmonic Compensation
Range
|
2nd~50th Order |
Monitoring |
4.3 inch LCD Displayer
Or
7 inch Centralized Monitoring
|
Full response time
|
≤10ms |
Power Loss |
<3% Rated Power |
IGBT Frequency
|
20KHz |
Harmonic Spectrum |
2nd~50th Harmonic Order |
Protective function
|
16 Ways Protection |
Design
Approoval
|
EN50065/60146/62477
IEC61000-4-2/5/6/4-12
IEC61000-6-4-2
|
Communication
Interface
|
RS485,Ehernet |
Certificate |
TUV CE/AS/URL |
Communication
Protocol
|
MODBU S-RTU protocol |
|
|
Model |
30A /50A |
75A/100A |
150A |
Wall Mounted
Dimensions(mm)
|
423W*88D*550H |
503W*190D*597H |
503W*220D*608H |
Rack Mounted
Dimensions(mm)
|
452.5W*450D*86H |
550.6W*540D*190H |
558W*540D*220H |
Net Weight |
14KGS |
34KGS/37KGS |
44KGS |
Protection Class |
IP 20 |
3. Product feature
※ Whole compensation or selectable Dual reactive compensation (capacitive & inductive)
Three-phase unbalance compensation Harmonic elimination rate>97% PF>0.99
※ Safety and reliability :Top brand IGBT DSP chip, high speed and reliable performance
Perfect equipment and production system
※ Low thermal loss (≤3% of rated APF kVA), efficiency ≥ 97%
※ High harmonic filtering rate: Up to 98%
※ High stability: Infinite impedance to grid, avoids harmonic resonance problems
※ Flexible application: Modular design, embedded in standard or customized cabinet
※ High harmonic filtering rate: Up to 98%
※ Modular design Easy installation and maintenance: Plug-in installation for APF module replacement and expansion
※ Wide capacity range: 50A~750A for a single cabinet, or customized
4.Advanced system performance
Advanced 3 level topology design
DSP+FPGA high speed operational capability
Automatic limiter without overload
Protection:overvoltage,overcurrent,over teaperature.Etc 16 ways protection
Communication:Ethernet,RS485 Etc.
5.Working Principle
Dynamic harmonic compensation filter AHF is a direct current-space-vector control active power filter (APF) based on a three-level neutral-point-clamped (NPC) voltage-source inverter.AHF is connected in parallel with non-linear loads, and uses external current transformers (CT) to detect the load current. It calculates each order harmonic current , and then generates a compensating current with the same amplitude but opposite phase angles to offset the harmonics.