|
BTS-20V10A Battery tester |
|
Model Number: |
BTS- |
20 |
V |
10 |
A |
Battery tester |
Material code: |
CT-3008 |
-20V10A |
- |
NA |
- |
P |
items |
Parameter |
Input power |
AC 220V ±10% / 60Hz |
Input active power |
2228 |
W |
resolution ratio |
AD:16bit;DA:12bit |
Input impedance |
≥1MΩ |
voltage |
Constant voltage range |
100mV~20V |
|
Minimum discharge voltage |
2.5V |
accuracy |
± 0.1% of FS |
stability |
± 0.1% of FS |
current |
Output range/channel |
50mA~10A |
accuracy |
± 0.1% of FS |
Constant voltage cut-off current |
0.02A |
stability |
± 0.1% of FS |
power |
Output range/channel |
200W |
stability |
± 0.2% of FS |
time |
Current response time |
maximum current rising time:20ms |
working step time range |
≤(365*24)h/working step |
Time format00:00:00(h,min,s) |
Data record |
Record data conditions |
Minimum sampling time:1s |
Minimum sampling voltage:40mV |
Minimum sampling current:20mA |
Record frequency |
1Hz |
Charge |
Charge mode |
constant-current charge,constant-voltage charge,constant voltage and current charge |
cut-off conditions |
Voltage,current,relative time,capacity,-△;V |
discharge |
Discharge mode |
constant current discharge, constant watt discharge |
cut-off conditions |
Voltage,current,relative time,capacity,-△;V |
cycle |
Loop test range |
1~65535 times |
Single cycle working steps |
254 |
Loop nest |
Nested loop function,max 3 layers |
Protection |
● Data Protection |
● off-line test |
● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time |
●anti reverse connection |
IP Protection Class |
IP20 |
Channel feature |
constant current and voltage source ;double closed-loop; |
|
Channel control mode |
independent |
|
Current/voltage detection sampling |
four-wire connection |
|
noise |
<85dB |
|
data base |
MySQL centralized management of test datas |
|
upper computer communication mode |
TCP/IP |
|
Data output mode |
EXCEL2003,2010,TXT |
|
Server disk Configuration |
500GB |
|
Server operating system |
Windows 7 |
|
communication interface |
ethernet |
|
Working environment requirement |
|
item |
parameter |
|
working temp. range |
0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) |
|
Storage temp. range |
-10℃~50℃ |
|
Working environment relative humidity range |
≤70% RH(no water vapor condensation) |
|
Storage environment relative humidity range |
≤80% RH(no water vapor condensation) |
|
Clamp specification and size |
|
item |
parameter |
|
Clamp type |
Polymer clamp |
|
Pic |
|
|
|
|
Alligator clamp |
Polymer clamp |
cable feet clamp |
|
Pictures are for reference only,real objects shall prevail.Choose one |
|
Cabinet size/unit(W*D*H)(mm) |
12U(19&”),600*600*740 |
|
Equipment pic |
|
|
Pictures are for reference only,real objects shall prevail. |
|
|